1. The five series at a glance
All series cure at 190–200 °C object temperature for 10–15 minutes at 80–120 µm. What changes between them is the tested durability.
| Series | Chemistry | Salt spray ISO 9227 | Humidity ISO 6270-1 | Xenon-arc ISO 16474-2 | Bend ISO 1519 | Role |
|---|---|---|---|---|---|---|
| E | Epoxy | 1440 h | — | — | ≤ 3 mm | Indoor parts, primer |
| EZ | Zinc-rich epoxy primer | ≥ 2000 h | — | — | ≤ 3 mm | Primer for steel structures |
| P480 | Weather-resistant polyester | 480 h | 240 h | 500 h | ≤ 2 mm | Outdoor topcoat |
| P720 | Weather-resistant polyester | 720 h | 480 h | 1000 h | ≤ 3 mm | Outdoor topcoat |
| P1680 | Weather-resistant polyester | 1000 h | 720 h | 1000 h | ≤ 4 mm | Outdoor topcoat, high exposure |
2. Values common to all series
| Application method | Electrostatic spray, 40–100 kV |
|---|---|
| Cure schedule | 190–200 °C (374–392 °F) object temperature for 10–15 min |
| Film thickness | 80–120 µm recommended; 80–180 µm working range |
| Impact (direct) | 50 kg·cm, ISO 6272-2 |
| Cross-cut adhesion | Class 0, ISO 2409 |
| Gloss, 60° | As agreed, ISO 2813 |
| Specific gravity | 1.2–1.7 g/cm³ (EZ 1.5–2.2 g/cm³, depends on zinc content) |
| Packaging | 25 kg carton; non-hazardous for road, sea and air transport |
| Storage | Cool, dry, below 35 °C (low-temperature-cure grades below 25 °C) |
| Shelf life | 6 months from date of manufacture |
Cure temperature is the object (metal) surface temperature, not the oven set-point. Oven settings must be adjusted to part mass, line speed and oven type so that the metal itself reaches 190–200 °C for 10–15 minutes.
3. Test conditions behind the numbers
Panels 70 × 150 × 0.6–0.8 mm phosphated steel (0.2–0.3 mm for flexibility, impact and cupping), cured under conditions agreed with the customer and conditioned 24 h before testing. Salt spray adhesion is checked 24 h after exposure ends. Xenon-arc weathering per ISO 16474-2 method 1: irradiance 0.51 W/m² at 340 nm, black-standard temperature 65 ± 2 °C, RH 40–60 %, spray cycle 18/102 min. Tests run in WANAN's CNAS-accredited laboratory (L15415, ISO/IEC 17025:2017). Values apply only to these methods and conditions; they are not a warranty of service life.
4. Choosing a series in six steps
- Define substrate and pretreatment. Steel, galvanised steel or aluminium, and the conversion coating on your line. Every TDS value is generated on phosphated steel panels.
- Define the service environment. Indoor or sheltered parts can use E epoxy. Outdoor exposure needs a weather-resistant polyester, because epoxy chalks under UV.
- Pick a single coat or a system. For aggressive outdoor steel, consider E or EZ primer plus a P series topcoat, qualified as a system.
- Match the test target. Compare the TDS values: salt spray 1440 h (E), ≥ 2000 h (EZ), 480 / 720 / 1000 h (P480 / P720 / P1680); xenon-arc 500 h (P480) or 1000 h (P720, P1680).
- Check labels the project requires. QUALICOAT projects need the approved system on P-1436 or P-1982; outdoor electrical enclosures for North America may need UL 1332 model WA-DQ 001A.
- Confirm on your line. Request sample powder and colour panels and run a line trial before final selection.
5. Application × series matrix
| Application | E | EZ | P480 | P720 | P1680 | Also relevant |
|---|---|---|---|---|---|---|
| Architectural aluminium & facades | — | — | ● | ● | ● | QUALICOAT P-1436 / P-1982 approved systems |
| Home appliances | ● | ○ | ● | ● | ● | E for indoor parts; P series for outdoor AC units |
| Energy storage & electrical enclosures | ● | ● | ● | ● | ● | UL 1332 model WA-DQ 001A for outdoor steel enclosures |
| Pipeline & heavy-duty corrosion | ● | ● | ○ | ○ | ○ | FBE / 3PE: dedicated grade qualified per project |
| Furniture & metal products | ● | ○ | ● | ● | ● | E indoors; P series outdoors; textures and metallics |
| Industrial equipment & machinery | ● | ● | ● | ● | ● | E or EZ primer + P series topcoat for exposed parts |
| Automotive & transport components | ● | ● | ○ | ○ | ○ | IATF 16949:2016; P series where appearance matters |
● candidate series · ○ as primer or topcoat within a two-coat system · — not a candidate. Final selection follows trial panels on your line.
6. Primer + topcoat systems
For aggressive outdoor steel, structural parts, energy-storage cabinets and machinery, an E or EZ primer sits under a P480, P720 or P1680 topcoat. Single-coat TDS values cannot be added together: the system is tested as a system.
- Fix the system and the target. Write down primer, topcoat, film thickness for each coat and the result the specification requires.
- Prepare panels on your line. Use production pretreatment. TDS values come from phosphated steel; your line sets the real ceiling for adhesion and corrosion life.
- Apply and cure as in production. Apply the primer, then the topcoat, using the cure schedule you will really run, and record the object-temperature profile.
- Test inter-coat adhesion first. Cross-cut (ISO 2409), impact (ISO 6272-2) and bend (ISO 1519) on the two-coat film reveal cure mismatch early.
- Run humidity and salt spray on the system. Test the combined system to ISO 6270-1 and ISO 9227. WANAN's CNAS-accredited laboratory can run these during qualification.
- Freeze the parameters. Record film thicknesses, cure profile and batch numbers in the qualification file before release.
7. Project labels: QUALICOAT and UL 1332
QUALICOAT (architectural aluminium)
- WANAN is a QUALICOAT approved powder manufacturer: P-1436 (Class 1, gloss category 3, metallic extension) and P-1982 (Class 2, gloss category 2), both valid until 31 December 2026 and verifiable in the QUALICOAT approvals database at qualicoat.net.
- Class 1 is the standard architectural quality; Class 2 is super-durable, with stricter accelerated-weathering and three-year Florida gloss-retention requirements.
- P480, P720 and P1680 are characterised by their ISO test results and are not themselves the labelled systems. Ask for the approved system on P-1436 or P-1982 when a project requires the label.
- P-1436 lists RAL 7030 as a banned colour for its Class 1 system.
- The finished component carries the label only when coated by a QUALICOAT-licensed applicator; WANAN supplies the powder and approval documents.
UL 1332 (steel enclosures of outdoor electrical equipment)
- UL Certificate of Compliance UL-US-2582808-0 (report MH67657-20250827, issued 29 August 2025): model WA-DQ 001A evaluated under UL 1332 (Edition 5) as a recognized component in category DTOV2 — organic coatings for steel enclosures of outdoor-use electrical equipment.
- Scope: 1-coat system on pretreated SPCC cold-rolled steel. Other WANAN series (E, EZ, P480, P720, P1680) are specified by their own TDS values and are not covered by the UL recognition.
- A recognized component coating is one input to the enclosure manufacturer's own UL investigation; the coating certificate does not by itself authorise any UL Mark on the finished enclosure.
8. From enquiry to release
- Enquiry & part data. Substrate, pretreatment, service environment, current system, oven profile and specification.
- Candidate series & samples. Series proposal with TDS basis; colour-matched sample powder and panels.
- Line trial. Trial panels or production parts sprayed on the customer's line; object-temperature profile recorded.
- Laboratory qualification. Adhesion, impact, bend, humidity, salt spray, weathering in the CNAS-accredited laboratory or per the customer's programme.
- Release & batch control. Production under ISO 9001 / IATF 16949; batch testing; certificate of analysis; 25 kg cartons.
9. Common mistakes
- Choosing by series name: P1680 is a designation, not 1680 h of salt spray (its result is 1000 h).
- Using epoxy E on parts exposed to sunlight.
- Adding primer and topcoat values together, or quoting the EZ primer's ≥ 2000 h as the system result.
- Assuming a P series is itself a QUALICOAT-labelled product.
- Reading the oven set-point as the cure temperature: the metal itself must reach 190–200 °C for 10–15 minutes.
- Checking film thickness only on flat panels: edges, welds and inside corners usually carry less film.
- Changing either powder after qualification without re-testing.
10. Compliance
Management systems certified to ISO 9001:2015, ISO 14001:2015 and ISO 45001:2018; design and manufacturing of thermosetting powder coatings certified to IATF 16949:2016. SGS reports (2026) on WANAN powder coating samples cover RoHS (EU) 2015/863, REACH SVHC screening, soluble heavy metals and California Proposition 65 (lead, cadmium, phthalates); results apply to the tested samples.
11. Standards referenced
| ISO 9227 | Neutral salt spray |
|---|---|
| ISO 6270-1 | Humidity resistance |
| ISO 16474-2 | Xenon-arc weathering |
| ISO 2813 | Gloss, 60° |
| ISO 2409 | Cross-cut adhesion |
| ISO 6272-2 | Impact |
| ISO 1519 | Mandrel bend |
| ISO 15184 | Pencil hardness |
| UL 1332 | Organic coatings for steel enclosures of outdoor-use electrical equipment |
| QUALICOAT | Quality label for coatings on architectural aluminium |
| ISO/IEC 17025:2017 | Laboratory competence (CNAS L15415) |
Performance data are valid only for the test methods, panels and cure conditions stated. They do not constitute a service-life warranty. Minimum order quantity, lead time and Incoterms are confirmed per project. Source: WANAN technical data sheets and wanancoat.com. Edition 1, 3 November 2026.