ISO 9001 · 14001 · 45001IATF 16949QUALICOATUL 1332CNAS L15415
sales@wanancoat.com  ·  +86-13559663052
  1. Home
  2. Applications
  3. Energy storage & electrical enclosures

Application

Powder coatings for energy storage & electrical enclosures

For energy-storage cabinets, EV chargers, photovoltaic structures, distribution boxes, inverter housings and battery-pack metal structures, WANAN proposes E or EZ as the anti-corrosion primer and P480, P720 or P1680 weather-resistant polyester as the topcoat (up to 1000 h salt spray, 720 h humidity, 1000 h xenon-arc). For steel enclosures of outdoor-use electrical equipment, WANAN's model WA-DQ 001A is a UL 1332 recognized component coating (UL-US-2582808-0).

Energy storage & electrical enclosures

Who this is for

Energy-storage system integrators, EV-charger manufacturers, PV mounting-structure fabricators, distribution and control cabinet makers, inverter and battery-pack housing suppliers, sheet-metal structure fabricators and their coating subcontractors.

What buyers need to solve

  • Corrosion under outdoor exposure, condensation, salt fog or high humidity.
  • Energy-storage cabinets, chargers and PV structures need both appearance and weathering performance.
  • Primer-topcoat adhesion, cure window and batch stability in multi-layer systems.
  • Project customers require TDS, SDS, test methods and line-trial records; outdoor electrical enclosures may require specific material systems and third-party documents.
Cabinet doors and enclosure panels before the curing oven
Cabinet doors and enclosure panels before the curing ovenOutdoor enclosures combine a corrosion-resistant primer with a weather-resistant topcoat, qualified as one system.

Candidate series and the logic behind them

Requirement / partCandidateBasis
General structural anti-corrosionENeutral salt spray 1440 h (ISO 9227)
Higher anti-corrosion primer requirementEZZinc-rich epoxy primer, salt spray ≥ 2000 h
Outdoor weather-resistant topcoatP480 / P720 / P1680Salt spray 480–1000 h · humidity 240–720 h · xenon-arc 500–1000 h
Steel enclosures of outdoor-use electrical equipment, UL 1332WA-DQ 001AUL Recognized Component, 1-coat on pretreated SPCC, UL-US-2582808-0
Primer + weather-resistant topcoat systemEZ or E + P seriesQualified as a system on trial panels
Candidate series shorten selection — the final choice is confirmed on your own parts after a line trial, taking pretreatment, film thickness, object temperature and your specification into account.

Electrical-insulation powders for motors, batteries and electrical components are handled as a separate requirement from cabinet corrosion protection and are proposed with their own dielectric data.

What is verified before release

Test dimensionFocus
CorrosionSalt spray; edges and weld zones; system compatibility
WeatheringXenon-arc, colour and gloss change
HumidityCondensation and humidity performance
System matchPrimer-topcoat adhesion, cure and inter-coat compatibility
DocumentationUL scope, project standard, specified model, substrate and system

How an enclosure project runs. Cabinet environment (indoor, outdoor, coastal) and any UL requirement → a single-coat P series candidate or an EZ primer + P1680 system; model WA-DQ 001A where a UL 1332 recognized coating is specified → trial panels on the customer's steel and pretreatment → combined-system salt spray, humidity and inter-coat adhesion in WANAN's CNAS-accredited laboratory (L15415) → data for the enclosure maker's own UL investigation, then release. See manufacturing & quality.

Enclosure corner, hinge and louvres after a humidity test
Enclosure corner, hinge and louvres after a humidity testSalt spray on edges and weld zones, condensation and xenon-arc weathering are checked per the project standard.

Frequently asked questions

Which WANAN coating is UL 1332 recognized?

UL Certificate of Compliance UL-US-2582808-0 (issued 29 August 2025) covers representative samples of WANAN model WA-DQ 001A as a UL 1332 recognized component coating — category DTOV2, coatings for steel enclosures of outdoor-use electrical equipment, 1-coat system on pretreated SPCC cold-rolled steel. The recognition applies to that model and system only; it does not extend to other WANAN series.

Can an EZ primer and P1680 topcoat be specified for a coastal energy-storage cabinet?

EZ zinc-rich primer under a P1680 weather-resistant polyester topcoat is a common candidate system for coastal or industrial-atmosphere cabinets. Single-coat TDS values cannot be added, so the two-coat system is qualified on trial panels for inter-coat adhesion, cure matching and combined-system salt spray. WANAN's CNAS-accredited laboratory runs these tests during project qualification.

Does cabinet corrosion protection also cover electrical insulation?

No. Structural corrosion protection of a cabinet or housing and electrical insulation of motors, batteries or bus components are separate requirements. WANAN handles insulation with dedicated insulating powder grades and their own dielectric strength, thermal-cycling and withstand-voltage data. Both requirements can be captured in one enquiry, but they are matched to different products.

Other applications

Technical support

Talk to our technical team

Send the substrate, service environment and your current cure window. We reply with candidate series, TDS and sample options.